OPERATION
B–63604EN/01
11. SETTING AND DISPLAYING DATA
633
By moving the tool until it reaches the desired reference position, the
corresponding tool offset value can be set.
Procedure for counter input of offset value
1 Manually move the reference tool to the reference position.
2 Reset the relative coordinates along the axes to 0 (see subsec.
III–11.1.2).
3 Move the tool for which offset values are to be set to the reference
position.
4 Select the tool compensation screen. Move the cursor to the offset
value to be set using cursor keys.
OFFSET/GEOMETRY O0001 N00000
NO. X Z. R T
G 001 0.000 1.000 0.000 0
G 002 1.486 –49.561 0.000 0
G 003 1.486 –49.561 0.000 0
G 004 1.486 0.000 0.000 0
G 005 1.486 –49.561 0.000 0
G 006 1.486 –49.561 0.000 0
G 007 1.486 –49.561 0.000 0
G 008 1.486 –49.561 0.000 0
ACTUAL POSITION (RELATIVE)
U 0.000 W 0.000
V 0.000 H 0.000
>X_
HND **** *** *** 16:05:59
[NO,SRH][ MEASUR ][ INP.C. ][ +INPUT ][ INPUT ]
5 Press address key
X
(or
Z
) and the soft key [INP.C.].
When the above operations are performed on the tool geometry
compensation screen, tool geometry compensation values are input and
tool wear compensation values do not change.
When the above operations are performed on the tool wear compensation
screen, tool wear compensation values are input and tool geometry
compensation values do not change.
11.4.4
Counter Input of Offset
value
Explanations
D Geometry offset and
wear offset