OPERATION
B–63604EN/01
11. SETTING AND DISPLAYING DATA
637
3–2 Press soft key [WEAR] to display the tool wear compensation
values along the Y–axis.
OFFSET/WEAR O0001 N00000
NO. Y
W 01 10.000
W 02 0.000
W 03 0.000
W 04 40.000
W 05 0.000
W 06 0.000
W 07 0.000
W 08 0.000
ACTUAL POSITION (RELATIVE)
U 100.000 W 100.000
>_
MDI **** *** *** 16:05:59
[ WEAR ][ GEOM ][ ][ ][ (OPRT) ]
4 Position the cursor at the offset number to be changed by using either
of the following methods:
D Move the cursor to the offset number to be changed using page
keys and cursor keys.
D Type the offset number and press soft key [NO.SRH].
5 Type the offset value.
6 Press soft key
[WEAR]. The offset value is set and displayed.
OFFSET/WEAR O0001 N00000
NO. Y
W 01 10.000
W 02 0.000
W 03 0.000
W 04 40.000
W 05 0.000
W 06 0.000
W 07 0.000
W 08 0.000
ACTUAL POSITION (RELATIVE)
U 100.000 W 100.000
>_
MDI **** *** *** 16:05:59
[ NO.SRH ][ MEASUR ][ INP.C. ][ +INPUT ][ INPUT ]