Series 30i-MODEL A, Rapid traverse override 0.1% Additional Manual Page 1

Additional Manual
TECHNICAL REPORT NO. TMN 04/020E
Date :Mar .30, 2004
General Manager of
Software Laboratory
FANUC Series 30i-A Newly additional functions
1. Communicate this report to:
Your information only
GE Fanuc-N, GE Fanuc-E
FANUC Robotics
MILACRON
Machine tool builder
Sales agency
End user
2. Summary for Sales Documents
3. Notice
Applied software of FANUC Series 30i-A
G001/22(V) or later
G011/22(V) or later
G021/22(V) or later
4. Attached Document
Drawing No. refer to attached table
Copy :
FLB1 Manager (2 pages from cover)
FLB2 Manager (2 pages from cover)
FLB3 Manager (2 pages from cover)
Original section of issue
Vice
General
Manager
Manager Chief
Person in
Charge
No. FLB1-04/2218
Date Mar. 30, 2004
ADE

Contents Summary of Series 30i-MODEL A, Rapid traverse override 0.1% Additional Manual

  • Page 1TECHNICAL REPORT NO. TMN 04/020E Date :Mar .30, 2004 General Manager of Software Laboratory FANUC Series 30i-A Newly additional functions 1. Communicate this report to: Your information only GE Fanuc-N, GE Fanuc-E FANUC Robotics MILACRON Machine tool builder Sales agency End user 2. Summary for Sale
  • Page 2FANUC Series30i –A newly additional functions Drawing number Functions 1 A-79227E External Data Input 2 A-79226E One Touch Macro call 3 A-79196E Temporary absolute coordinate setting 4 A-79354E System alarm 5 A-79349E Touch Panel Control 6 A-79253E Distance coded linear scale interface 7 A-79364E Li
  • Page 3FANUC Series 30i-MODEL A Rapid traverse override 0.1% Specifications FANUC Series 30i-MODEL A Title Rapid traverse override 0.1% Draw. No. A-79367E Ed. Date Design Description page 1/7 Date Jan. 13, 2004 Design Approve
  • Page 4"7.1.7.1 Rapid traverse override" of the B-63943EN-1 CONNECTION MANUAL (FUNCTION) is replaced as following. FANUC Series 30i-MODEL A Title Rapid traverse override 0.1% Draw. No. A-79367E Ed. Date Design Description page 2/7 Date Jan. 13, 2004 Design Approve
  • Page 51.1.1.1 Rapid traverse override Overview An override of four steps (F0, 25%, 50%, and 100%) can be applied to the rapid traverse rate. F0 is set by a parameter (No. 1421). Also, 1% rapid traverse override select signal and 0.1% rapid traverse override select signal allow rapid traverse override ever
  • Page 6- 0.1% step rapid traverse override selection signal 0.1% step rapid traverse override selection signal FHROV determines whether 1% step rapid traverse override is used or 0.1% step rapid traverse override is used. When signal HROV is 1 and signal FHROV is 0, 1% step rapid travers override is applie
  • Page 71% step rapid traverse override signals *HROV0 to *HROV6 [Classification] Input signal [Function] Applies override to the rapid traverse rate in the range of 0% to 100% in steps of 1%. [Operation] These seven signals give a binary code indicating an override applied to the rapid trave
  • Page 8Parameter 1421 F0 rate of rapid traverse override for each axis [Input type] Parameter input [Data type] Real axis [Unit of data] mm/min, inch/min, degree/min (machine unit) [Minimum unit of data] Depend on the increment system of the applied axis [Valid data range] Refer to the standard parameter s
  • Page 9#7 #6 #5 #4 #3 #2 #1 #0 8001 OVE [Input type] Parameter input [Data type] Bit path #2 OVE Signals related to dry run and override used in PMC axis control 0: Same signals as those used for the CNC 1: Signals specific to the PMC The signals used depend on the settings of these parameter bits as indic