4. DESCRIPTION OF PARAMETERS
B–63090EN/02
124
MDL Display of the modal state on the program display screen
0 : Not displayed
1 : Displayed (only in the MDI mode)
#7
JSP
3108
#6
SLM
#5 #4
WCI
#3 #2 #1 #0
JSP SLM WCI PCT
[Data type] Bit
PCT On the 7–pieces type soft key display program check screen and
12–pieces type soft key display position screen, T code displayed
0 : is a T code specified in a program (T).
1 : is a T code specified by the PMC (HD. T/NX. T)
WCI On the workpiece coordinate system screen, a counter input is:
0 : Disabled.
1 : Enabled.
SLM The spindle load meter is:
0 : Not displayed.
1 : Displayed.
>_ Sxxxxx Lxxx%
EDIT *** *** *** 12:34:56
[] [] [] [] []
Display of the
spindle load
meter
NOTE
1 This parameter is enabled only when the DPS parameter (bit
2 of parameter No.3105) is set to 1.
2 This is valid only for serial spindles.
JSP On the current position display screen and program check screen, jog feed is:
0 : Not displayed.
1 : Displayed.
NOTE
In manual operation mode, the jog feedrate is displayed. In
automatic operation mode, the dry run feedrate is displayed.
In each case, the feedrate to which a manual feedrate
override has been applied is displayed.
JOG F 8000 PART COUNT 15
RUN TIME 1H17M CYCLE TIME 1H15S
ACT.F 1000 MM/M
MEM STRT MTN *** 12:34:59
[ ] [ ] [ ] [ ] [ ]
Jog
feedrate