OPERATION11. SETTING AND DISPLAYING DATA
B–63614EN/01
678
The extended tool life management function provides more detailed data
display and more data editing functions than the ordinary tool life
management function.
Moreover, if the tool life is specified in units of time, the time which has
been set can be increased or reduced (life count override).
When bit 6 (EXT) of parameter 6801 is set to 0, the ordinary tool life
management function applies. See III–11.4.11.
Procedure for displaying and Setting extended tool life management
1 Press function key
OFFSET
SETTING
.
2 Press the continuous menu key
to display chapter selection soft
key
[TOOLLF].
3 Press soft key
[TOOLLF] to display the tool life management data
screen.
On this screen, place the cursor on a group of items to be edited.
4 Press soft key
[(OPRT)].
5 Press soft key
[EDIT].
The extended tool life management data editing screen for the group
indicated by the cursor is the displayed.
LIFE DATA EDIT GROUP : 001 O0010 N00001
TYPE : 1 (1:C 2:M) NEXT GROUP: ***
LIFE : 9800 USE GROUP : ***
COUNT : 6501 SELECTED GROUP : 001
NO. STATE T–CODE H–CODE D–CODE
01 * 0034 011 005
02 # 0078 000 033
03 @ 0012 004 018
04 * 0056 000 000
05 0090 000 000
06 * 0076 023 012
> _
MDI **** *** *** 16:05:59
[ INSERT ] [ DELETE ] [ STATE ] [ END ] [ INPUT ]
Tool life management data can be edited as follows:
6 Select the
MDI mode.
7 Stop, pause, or reset the CNC by the feed hold, single block stop, or
reset operation (tool life management data cannot be edited while data
is set by a program.).
The following editing can be performed. See each step for details:
⋅ Setting the life count type, life value, current life count,
and tool data (T, H, or D code) : 7–1
⋅ Adding a tool group : 7–2
⋅ Adding a tool number (T code) : 7–3
11.4.12
Displaying and Setting
Extended Tool Life
Management
Procedure
TOOLLF
Continuous menu key