Contents Summary of FANUC Series 16i/18i/21i Additional Manual
Page 1FANUC Series 16i/18i/21i–B FANUC Series 18i–MB5 Dual Check Safety Spindle Controlled Stop at Exceeding Safe Speed Specifications CONTENTS 1. General ……………………………………………………………………………………………………………..2 2. Specifications ……………………………………………………………………………………………………..2 3. Parameters ……………………………………………………………………………………
Page 21. General In dual check safety function, when the spindle alarm occurs, power-down causes the spindle motor to continue rotating for a certain time. By using this function, the spindle stops with controlling when the exceeding spindle safety speed alarm occurs. 2. Specifications In dual check safet
Page 33. Parameters #7 #6 #5 #4 #3 #2 #1 #0 4399 CTLSTP [Data type] Bit spindle axis CTLSTP In dual check safety function, when the exceeding spindle safety speed alarm occurs,: 0 : The controlled stop function is disabled. 1 : The controlled stop function is enable. (controlled stop and power-down after
Page 44. Reference FANUC Series 16i/18i/21i Dual Check Safety OPERATOR’S MANUAL (B-63494EN) FANUC Series 16i/18i/21i - B, 18i - MB TITLE Dual Check Safety Spindle Controlled Stop at Exceeding Safe Speed Specifications Draw No. A-90080E Edit Date Design Description Sheet 4/4 Date 2005.05.31 Desig. M.Ito Ap