Contents Summary of FS16/18-MC/TC, FS16i/18i/21i-MA/TA General Purpose Retract (A-63678E) Additional Manual
Page 1TECHNICAL REPORT (Manual) No. TMN99/040E Date March, 21, 1999 General Manager of Software Laboratory FS16/18-MC/TC,FS16i/18i/21I-MA/TA GENERAL PURPOSE RETRACT 1. Communicate this report to the destinations marked with: O Your information O GE Fanuc-N, GE Fanuc-E FANUC Robotics CINCINNATI MILACRON O
Page 2FANUC Series 16i/18i/21i-MA/TA FANUC Series 16/18-MC/TC SPECIFICATIONS FOR GENERAL PURPOSE RETRACT Contents 1 General --------------------------------------- 2 2 Signals ----------------------------------- 3 3 Timing chart ------------------------------ 4 4 Parameters -------------------------------
Page 31. General When the retract signal RTRCT is turned to “1” (the rising edge is detected) in auto mode or manual mode, the axis set in bit 0 (RTR) of the parameter No.7730 moves (retracts) by the amount set in the parameter No.7741. Upon the completion of retraction, the retract completion signal RTRC
Page 42. Signals Retract signal RTRCT [Classification] Input signal [Function] Performs retraction for the axis specified with a parameter. [Operation] When this signal turns to “1”, the control unit performs the following: Detects the rising edge of this signal, and performs retraction on the ax
Page 54. Timing chart (1) ON/OFF timing of RTRCT and RTRCTF signals RTRCT RTRCTF Moving Retract movement Moving command (2) The stopping of retract by the reset RTRCT RTRCTF Moving Retract movement stopping RST FANUC Series 16i/18i/21i -MA/TA TITLE FANUC Series 16/18 -MC/TC GENERAL PURPOSE RETRACT 01 1999
Page 64. Parameters 7 6 5 4 3 2 1 0 7730 RTRx C C C C C C C C [Data type] Bit axis RTRx The retract function is : 0 : Disabled. 1 : Enabled. 7740 Feedrate during retraction for each axis [Data type] 2 Words axis [Unit of data and valid data range] Increment system Unit of data Valid range IS-B IS-C Millim
Page 75. Notes (1) Feedrate override is not supported for retracting. (2) Interlock is supported for retracting. (3) Machine lock is supported for retracting. Retract completion signal is output when retract operation is completed in the machine lock condition. (4) Feed hold is not supported for retractin