Changing of connection in FL-C4000A for CE marking, we report that the connection between oscillator and machine will be changed in FL-C4000A for CE marking. Additional Manual Page 2

Additional Manual
Changing of connection in
FL-C4000A for CE marking
01 00.06.12 TOGO Newly
••• •• •••• ••
•••••••••
••••• 001/2
••••••••••••
Changing of connection in FL-C4000A for CE marking
We report that the connection between oscillator and machine will be changed
in FL-C4000A for CE marking.
•Overview•
In FL-C4000A for CE marking, it is necessary to connect CNL1, COP1,
OFI1,2, and CP1A(or ON/OFF) between oscillator and machine. In this
changing, OFI1,2 and CP1A will be included in CNL1. As a result, the
connection cables between oscillator and machine are reduced to only CNL1
and COP1.
Caution) In case of FS16-LB, it is not necessary to connect the ON/OFF
signal of AC200V from
CNC into IF PCB, because ON/OFF status of oscillator is
controlled by the signal
of A1,A2 in CNL1.
•Detail of connector•
CONNECTOR DETAIL
COP1 Connector of I/O signal from CNC.
Connection with the optical fiber.
CP1A It is not necessary to connect this connector from now
on.
(Oscillator
s ON/OFF signal with FS16i-L.)
(Connect DC24V controlled by CNC.)
CNL1 Connector between oscillator and machine.
IF
PB
IF
PB
oscillator machin
COP1
CNL1
[after
Connection diagram of
••••
A1 IB1 B1 IB2
A2 SC B2
A3 SHL1 B3 SHL2
A4 RUN1 B4 RUN2
A5 EMS1 B5 EMS2
A6 A1 B6 A2
A7 OFI1 B7 OFI2
oscillator machin
COP1
CP1A
*)
OFI1,2
CNL1
[before
Connection diagram of ••••
A1 IB1 B1 IB2
A2 SC B2
A3 SHL1 B3 SHL2
A4 RUN1 B4 RUN2
A5 EMS1 B5 EMS2
A6 A1 B6 A2
A7 B7
A8 PF1 B8 PF2
*) When FS16i-L is chosen, connect to
CP1A.
When FS16-LB is chosen, connect to
••

Contents Summary of Changing of connection in FL-C4000A for CE marking, we report that the connection between oscillator and machine will be changed in FL-C4000A for CE marking. Additional Manual

  • Page 1TECHNICAL REPORT NO.TML 00/005E Date 27 June, 2000 General Manager of Laser Laboratory •••Changing of connection in FL-C4000A for CE marking• •1. Communicate this report to: •••• •• Your information •• GE FANUC-NA, GE FANUC-E FANUC Robotics CINCINNATI MILACRON •• Machine tool builder Sales agency En
  • Page 2Changing of connection in FL-C4000A for CE marking We report that the connection between oscillator and machine will be changed in FL-C4000A for CE marking. •Overview• In FL-C4000A for CE marking, it is necessary to connect CNL1, COP1, OFI1,2, and CP1A(or ON/OFF) between oscillator and machine. In t
  • Page 3•Detail of signal• SIGNAL DETAIL ON,OFF It is not necessary to connect these terminals from now on. (Oscillator’s ON/OFF signal with FS16-LB.) (Connect AC200V controlled by CNC.) PF1,PF2 Shunt trip of main breaker in oscillator. When it is applied DC24V(PF1:+24V•PF2:0V) to these terminals, main brea