1. EXPLANATIONS
When the serial spindle parameters (No.4000 No.4799) are set by PMC
window function, these data are transferred to serial spindle amplifier
immediately.
For the details about PMC window function, refer to PMC programming
manual.
2. PARAMETER
#7 #6 #5 #4 #3 #2 #1 #0
8703
WSP
[Data type] Bit
WSP When the serial spindle parameters (No.4000 No.4799) are
set by PMC window function, these data are:
1 : transferred to serial spindle amplifier immediately.
0 : not transferred to serial spindle amplifier immediately.
3. NOTE
1) This function is not valid when all spindle axes are assigned in the PMC
window function code 18. (axis assignment: -1)
2) Don't change the serial spindle parameters (No.4000 No.4799) by
PMC window function while:
- the spindle unit is starting when NC power is ON, or
- the serial spindle parameters are being set from the MDI panel,
RS-232-C or programmable data input G10.

Contents Summary of Serial Spindle Parameter Set by PMC WINDOW Function Other

  • Page 1FANUC Series 16/18-B/C, 16i/18i/21i SERIAL SPINDLE PARAMETER SET BY PMC WINDOW FUNCTION SPECIFICATIONS CONTENTS 1. EXPLANATIONS .......... 2 2. PARAMETER .......... 2 3. NOTE .......... 2
  • Page 21. EXPLANATIONS When the serial spindle parameters (No.4000 ∼ No.4799) are set by PMC window function, these data are transferred to serial spindle amplifier immediately. For the details about PMC window function, refer to PMC programming manual. 2. PARAMETER #7 #6 #5 #4 #3 #2 #1 #0 8703 WSP [Data t