1. EXPLANATIONS
When the serial spindle parameters (No.4000 ∼ No.4799) are set by PMC
window function, these data are transferred to serial spindle amplifier
immediately.
For the details about PMC window function, refer to PMC programming
manual.
2. PARAMETER
#7 #6 #5 #4 #3 #2 #1 #0
8703
WSP
[Data type] Bit
WSP When the serial spindle parameters (No.4000 ∼ No.4799) are
set by PMC window function, these data are:
1 : transferred to serial spindle amplifier immediately.
0 : not transferred to serial spindle amplifier immediately.
3. NOTE
1) This function is not valid when all spindle axes are assigned in the PMC
window function code 18. (axis assignment: -1)
2) Don't change the serial spindle parameters (No.4000 ∼ No.4799) by
PMC window function while:
- the spindle unit is starting when NC power is ON, or
- the serial spindle parameters are being set from the MDI panel,
RS-232-C or programmable data input G10.