Edit
2
21
Data Si
nature
Descri
tion
FANUC Series 16
/18
/21
-TB
Spindle select by address P
(multi-spindle control)
A-77777E
Drawing No.
Title
Page
02 2003.4.8
M.Ito
Constant surface speed control is modified.
1. Specification
In multi-spindle control, when the parameter MPP(No.
3703#3) is set to 1, S command is sent to one spindle specified
by address P.
Spindle selection signals SWS1<G027#0>,SWS2<G027#1>,
SWS3<G027#2>, SWS4<G026#3>,SLSPA<G063#2> and
SLSPB<G063#3> don’t need to be used.
Note 1 This function is included in multi-spindle control.
Multi-spindle control is an optional function.
Note 2 The feed back of position coders must be selected with
PC2SLC, PC3SLC, PC4SLC signals.
Note 3 About the details of multi-spindle control, refer to
“FS16i/FS18i/FS21i CONNECTION MANUAL(FUNCTION)