2005/08/29
Edit
6/8
Data Si
nature
Descri
tion
FS16i/18i/21i-MB, 18i-MB5
Retraction for 3-dimentional rigid tapping
Specifications
A-90190EN
Drawing No.
Title
Page
4 Signal
Rigid tapping retraction start signal
RTNT <G062#6>
[Classification] Input signal
[Function] Start rigid tapping retraction during 3-dimensional coordinate conversion mode or
tilted working plane command mode
[Operation] When this signal is set to “1”, the control unit operates as follows:
• Start rigid tapping retraction
Rigid tapping retraction completion signal
RTPT <F066#1>
[Classification] Output signal
[Function] Notifies the completion of rigid tapping retraction during 3-dimensional coordinate
conversion mode or tilted working plane command mode
[Operation] This signal is set to “1” in the following case:
• Rigid tapping retraction has been completed.
This signal is set to “0” in the following case:
• Rigid tapping retraction start signal has been set to “0”
Signal address
#7 #6 #5 #4 #3 #2 #1 #0
G062 RTNT
#7 #6 #5 #4 #3 #2 #1 #0
F066 RTPT