2. Parameters
12350 Manual handle feed magnification m for each axis
[Data type] Word axis
[Unit of data] One time
[Valid data range] 1 to 127
This parameter sets the magnification for each axis when manual handle feed movement
selection signal MP1 and MP2 are set to “0” and “1”.
When this parameter is set to “0”, the setting value of the parameter No.7113 is used.
12351 Manual handle feed magnification n for each axis
[Data type] Word axis
[Unit of data] One time
[Valid data range] 1 to 1000
This parameter sets the magnification for each axis when manual handle feed movement
selection signal MP1 and MP2 are set to “1”.
When this parameter is set to “0”, the setting value of the parameter No.7114 is used.
Movement selection
signal
MP2 MP1
Movement
(Manual handle feed)
0 0
Least input increment × 1
0 1
Least input increment × 10
1 0
Least input increment × m
*1
1 1
Least input increment × n
*2
*1 When the setting value of the parameter No.12350 is “0”, the setting value of the
parameter No.7113 is used.
*2 When the setting value of the parameter No.12351 is “0”, the setting value of the
parameter No.7114 is used.
3
4
Edit
Apprv. Desig.
Sheet
Title
Draw
No.
Date
Design
Descri
tion
Date
May.17.2004
Sheet
FS16i/18i/21i - B, 18i - MB5, 0i - B
Manual handle feed magnification for each axis
Specifications
A-78860E