3. PARAMETER
SPR MPP
#1 #0 #2#3#4#5#7 #6
3703
[Data type] Bit type, common to all paths
When these parameters are modified, POWER MUST BE OFF alarm occurs.
SPR On 2- or 3-path lathe, the rigid tapping with spindle of another path function is:
0: Not available
1: Available
MPP In multi-spindle control, spindle select function by address P is
0: Not available
1: Available
Note 1 When this function is used, set the parameters No.3781-No.3784.
Note 2 This function is included in multi-spindle control. Multi-spindle control is an
optional function.
"The spindle select function by address P" can be applied to "The rigid tapping with spindle
of another path function
". Therefore, when doing rigid tapping using the spindle of the other
path, the rigid tapping spindle can be selected by the program command (by P code). This
specification is described about the case where above-mentioned two functions (parameters)
are set.
SPR MPP
Reference item
1 1
•
•
Improvement of Rigid tapping with spindle of another (Spindle select by address P)
Specifications (A-79156E)
(Note : This book)
Spindle select by address P (Multi-spindle control) Specifications
(A-77777E and A-77777E-1)
1 0
• Rigid tapping with spindle of another Specifications (A-78374E)
0 1
•
Spindle select by address P (Multi-spindle control) Specifications
(A-77777E and A-77777E-1)
0 0 -
(2)
Ed.
Page
Name
No.
Date
Contents
Draw u
FS16
i
/18
i
-TA/TB (2 or 3 path)
Improvement of Rigid tapping with spindle of another path
(Spindle select by address P) Specifications
A-79156E
2003.06.01
7/11
T. K
(2)
art chan
ed.
02
030703
Apprv.
Desig.
Desi
n
T. Kurokawa E. Genma