About set time of the laser
maintenance screen
A-78624E
Page
1 / 1
Recog
nition
Newly designed
M.Sato
Oct 12,2001
01
dded C5000-E, C6000E and
Oil mist decomposing element
Tsuge-s
hita
Oct 01,2004
02
About set time of the laser maintenance screen
When the parts working time screens of the laser maintenance screens are used, standard values of
set time are as follows.
The below standard setting times are the same as shortest time described at periodic maintenance in
oscillator maintenance manual (B-70125EN).
[Standard setting time of “CLEANING” screen]
item C1000-E C2000-E C4000-E C5000-E C6000-E
Output mirror
3000h 1500h 800h 1000h 1000h
Folding mirror
3000h 3000h 3000h 3000h 3000h
Rear mirror
3000h 1500h 800h 1000h 1000h
Shutter mirror
3000h 3000h 3000h 3000h 3000h
Optical compensation mirror 1
(B.P.L.U mirror 1)
-
Set at
Customer
Set at
Customer
- -
Optical compensation mirror 2
(B.P.L.U mirror 2)
-
Set at
Customer
Set at
Customer
- -
Coolant tube
3000h 3000h 3000h 3000h 3000h
[Standard setting time of “CHANGE” screen]
item C1000-E C2000-E C4000-E C5000-E C6000-E
Vane-pump oil
1500h 1500h 1500h 1500h 1500h
Vane-pump filter
3000h 3000h 3000h 3000h 3000h
Gas filter
12000h 12000h 12000h 12000h 12000h
Chiller coolant
1500h 1500h 1500h 1500h 1500h
Blower oil
1000h 1000h 1000h 1000h 1000h
Discharge-tube O-ring
6000h 6000h 6000h 6000h 6000h
Gas tube O-ring
6000h 6000h 6000h 6000h 6000h
Warning lamp
3000h 3000h 3000h 3000h 3000h
Oil mist decomposing element
10000h 10000h 10000h 10000h 10000h
[Standard setting time of “OTHER” screen]
item C1000-E C2000-E C4000-E C5000-E C6000-E
Vane-pump overhaul
10000h 10000h 10000h 10000h 10000h
Blower 1 overhaul
12000h 12000h 12000h 12000h 12000h
Blower 2 overhaul
- - -
12000h 12000h
Blower 3 overhaul
- - - - -
Blower 4 overhaul
- - - - -