EDT
DATE
FANUC Series 16i/18i-MB/TB
Simple spindle synchronous control
with any spindles
A-78964E
5/10
DS0100-04
DESIG.
DESCRIPTION
TITLE
NO.
PAGE
3. Signals
Simple spindle synchronous control signals
ESSYC1 to ESSYC4<G264#0 to G264#3>
[Classification] Input signal
[Function] Enable simple spindle synchronous control
[Operation] When ESSYC1 is 1, 1st spindle will be synchronized as slave.
When ESSYC2 is 1, 2nd spindle will be synchronized as slave.
When ESSYC3 is 1, 3rd spindle will be synchronized as slave.
When ESSYC4 is 1, 4th spindle will be synchronized as slave.
These signals are available only when the parameter SSY (No.3704#5) is 1.
Master for each slave is specified in the parameters No.4821 to 4824.
It is not available that one master spindle is synchronized with some slave
spindles.
Spindle parking signals
PKESE1 to PKESE4<G265#0 to G265#3>
[Classification] Input signal
[Function] Enable spindle parking in simple spindle synchronous control
[Operation] When PKESE1 is 1, parking function will be active for 1st spindle.
When PKESE2 is 1, parking function will be active for 2nd spindle.
When PKESE3 is 1, parking function will be active for 3rd spindle.
When PKESE4 is 1, parking function will be active for 4th spindle.