Display control card for FS 16i/18i/21i has changed (A-76081E-004) Additional Manual Page 2

Additional Manual
Graphic software 600W Series 60V2 Series
System boot function 60M3 All Editions 60M3 08E or later
Note) Basic function and Graphic software are stored in FROM module mounted on the mother board,
and System boot function is stored in FROM chip mounted on the CPU card.
If hardware and software are mismatched, the status of CNC or alarm becomes as follows.
Old PCB
In case Graphic software is 60V2 Series A message, which is ‘SOFT COMBINATION
ERROR(GRAPHIC)’, is displayed, and stops.
New PCB
In case mismatched System boot is
installed
CNC doesn’t start, and any messages are not
displayed.
In case Graphic software is 600W Series A message, which is ‘SOFT COMBINATION
ERROR(GRAPHIC)’, is displayed, and stops.
In case mismatched Basic function is
installed
CNC normally starts, and display based on
character is normally done. But graphic cannot
be displayed.
EDIT.
SHEET
DRAW. NO. CUST.
TITLE
002/2
DESCRIPTIONDESIG.DATE
Display control card for
FS16i/18i/21i has changed
A-76081E-004

Contents Summary of Display control card for FS 16i/18i/21i has changed (A-76081E-004) Additional Manual

  • Page 11. Outline Fanuc have developed new Display control card, on which new VGA chip is mounted, because the old VGA chip mounted on the present Display control card will be ended. Since July 1998, this new Display control card have been applied to FS16i/18i/21i. This new Display control card can be moun
  • Page 2Graphic software 600W Series 60V2 Series System boot function 60M3 All Editions 60M3 08E or later Note) Basic function and Graphic software are stored in FROM module mounted on the mother board, and System boot function is stored in FROM chip mounted on the CPU card. If hardware and software are mis