6
Edit
Apprv.
Apprv.Apprv.
Apprv.Desig.
Desig.Desig.
Desig.
Sheet
Title
Draw
No.
/
24
Date
DateDate
Date
Design
DesignDesign
Design
Descri
tion
Descri
tionDescri
tion
Descri
tion
Date
DateDate
Date
FANUC Series16i /18i /21i –MA/TA
Embedded Macro
A-77900E
2000.04.11
3. Detail
1) Program number
As for the embedded macro program number, the first program number is set to
parameter No.12011 and the last program number is set to No.12012. The
remainder program numbers become the user program numbers of the tape storage
memory area. When the keyword is matched the password (unlock state) and no
program exists, the parameters for embedded macro program number can be
changed.
Example) In case that the program No. is 4 digits
Parameter No. 12011 = 1234
Parameter No. 12012 = 5678
Embedded macro programs No. = O1234 to O5678
User programs No. = O0001 to O1233
O5679 to O9999
On the program list screen, the embedded macro program number is displayed as