Edit
Apprv. Desig.
Sheet
Title
Draw
No.
Date
Design
Descri
tion
Date
FANUC Series 16i /18i /21i – B, 18i – MB5
Optimal acc/dec decision at positioning
Specification
Oct.4.2004
9/9
A-79261E
4 Notes
(1) This function is invalid for the following feeds.
- Cutting feed
- Manual rapid traverse
- Positioning command of manual numerical control
- Positioning command of PMC axis control
- Positioning command of chopping function
(2) This function is invalid when the following function is attached.
- Angular axis control / Arbitrary angular axis control
- Positioning by optimal acceleration
- Block overlap in rapid traverse (Parameter RTO (No.1601#4) = 1)
(3) This function is invalid during the following modes.
- Polar coordinate command (G15/G16)
During the polar coordinate command mode, a time constant so that
the acceleration becomes minimum ratio is used, which is calculated by
the rapid traverse feedrate (parameter No.1420) and the time constant
(parameter No.1620, 1621) of the axis with parameter LRTx
(No.1610#3) = 1.