FANUC Series 16i/18i/21i-B Erase Screen Display Function on Custom Screen / PMC Screen Specifications Additional Manual Page 2

Additional Manual
2003/06/21 T.Inagaki
1. Specifications
In the current specification, when custom screen (macro executor or C
language executor) or PMC screen is displayed, the backlight ON/OFF can
not be done by pressing [CAN] and voluntary function key simultaneously.
By setting parameter 3207#3(SO2) to '1', it is improved as the erase screen
display function, realized by pressing [CAN] and voluntary function key
simultaneously, becomes available even if the screen of macro executor, C
language executor or PMC is displayed.
2. Parameter
#7 #6 #5 #4 #3 #2 #1 #0
3207 SO2
[Data type] Bit
SO2 E
rase screen display function, realized by pressing [CAN] and
voluntary function key simultaneously, is
:
0: Only available when CNC screen is displayed.
1: Available even if the screen of macro executor, C language
executor or PMC is displayed.
Caution
This function is unavailable with virtual MDI key.
Note
When this parameter is set, the power must be turned off before
operation is continued.
A-79643EN
FANUC Series 16i/18i/21i –B
Erase Screen Display function on Custom screen /
PMC screen
Title
Drawing No.
Page
Descri
p
tionDate Edit
2/2

Contents Summary of FANUC Series 16i/18i/21i-B Erase Screen Display Function on Custom Screen / PMC Screen Specifications Additional Manual

  • Page 1FANUC Series 16i/18i/21i-B Erase Screen Display function on Custom screen / PMC screen Specifications Title FANUC Series 16i/18i/21i –B Erase Screen Display function on Custom screen / PMC screen Drawing No. A-79643EN Page Edit Date Description 1/2 2003/06/21 T.Inagaki
  • Page 21. Specifications In the current specification, when custom screen (macro executor or C language executor) or PMC screen is displayed, the backlight ON/OFF can not be done by pressing [CAN] and voluntary function key simultaneously. By setting parameter 3207#3(SO2) to '1', it is improved as the eras