Concerning shifting Super CAP II T to Super CAPi T (Information) A-63450E Additional Manual Page 2

Additional Manual
01 98.04.06 New-registered
A-63450E
ED DATE DESIG.
DESCRIPTION
1/1
CUST.
SHEET
TITLE
DRAW.NO.
Concerning shifting
Super CAP II T
to Super CAPi T
Concerning shifting Super CAP II T to Super CAPi T(Information)
Current FS16
i
/18
i
-TA Super CAP II T is shifted to new FS16
i
/18
i
/21
i
-TA Super CAP
i
T,
since April 1998.
However, please be careful because the rule of an order is different between Super CAPi T
and Super CAP II T as follows.
Super CAP
i
T (New) Super CAP II T (Current)
Drawing No.
(Macro Library)
A08B-9001-J782#ZZ07
(for 1 path lathe)
A08B-9001-J783#ZZ07
(for 2 path lathe)
A08B-9001-J734#ZZ07
(for 1 path lathe)
A08B-9001-J735#ZZ07
(for 2 path lathe)
Drawing No.
(Additional Option)
A02B-????-J768
???? = 0236 : for FS16
i
-TA
0238 : for FS18
i
-TA
0247 : for FS21
i
-TA
A02B-????-J898
???? = 0236 : for FS16
i
-TA
0238 : for FS18
i
-TA
Custom software size
(*1)
The size adding the user’s macro
program size to the system
software size 2.25MB is
specified.
(In 2 path system, the above size
is always specified in both sides
of Main and Sub.
The specified size is always 3MB.
(In 2 path system, the above size
is always specified in both sides
of Main and Sub.
(*1) In Super CAPi T(A08B-9001-J782#ZZ07,A08B-9001-J783#ZZ07) and Super CAP II T(A08B-
9001-J734#ZZ07,A08B-9001-J735#ZZ07), the size of CAP system is 2.25Mbytes on one path
each. The user’s macro program can be occupied in the remainder.
Note1) Super CAPi T is available on FS21i-TA also.
Note2) Please install Super CAPi T to i-Series CNC with the following software.
• On and after DEF1-08 in case of FS21i-TA.
Note3) New functions are not added in Super CAP II T.
The new following functions is added in Super CAP
i
T.
1. Optional function
• Interference check on the animated drawing
???? = 0236 : for FS16i-TA
0238 : for FS18i-TA
0247 : for FS21i-TA
Note) This function is used with the following CNC system software.
On and after B1F1-14(FS16i-TA)
On and after BEF1-14(FS18i-TA)
On and after DEF1-09(FS21i-TA)
2. Normal functions
• Contour figure list input function
• Trapezoid groove pattern input function

Contents Summary of Concerning shifting Super CAP II T to Super CAPi T (Information) A-63450E Additional Manual

  • Page 1TECHNICAL REPORT NO.TMN 98/064 Date April.06.1998 General Manager of Software Laboratory Concerning shifting Super CAP II T to Super CAPi T (Information) 1. Communicate this report to: ○ Your information ○ GE Fanuc-N, GE Fanuc-E FANUC Robotics CINCINNATI MILACRON ○ Machine tool builder Sales agency
  • Page 2Concerning shifting Super CAP II T to Super CAPi T(Information) Current FS16i/18i -TA Super CAP II T is shifted to new FS16i/18i/21i-TA Super CAPi T, since April 1998. However, please be careful because the rule of an order is different between Super CAPi T and Super CAP II T as follows. Super CAPi