02 12/11/2004 T.N (2) added and modified
EDIT
Apprv.DESIG.
4
5
DATE DESIG.
DESCRIPTION
DATE
Binary Operation with Axes
Recomposition
-76565/02
TITLE
DRAW.NO.
SHEET
30/09/2004 T.Nakazato
G96,G97,G50 Surface speed constant control
∗ These are still temporary. They may be changed.
The operations except the above command can be executed in manual operation and
automatic operation as usual.
But high-speed interpolation mode can be canceled by changing the cancel signal of
high-speed interpolation mode from 0 to 1. <DI signal Gxxx.x> On the other hand, changing
the signal from 1 to 0 can restart high-speed interpolation mode. If the above G codes that are
prohibited in high-speed interpolation mode have to be used, cancel high-speed interpolation
mode temporarily by this signal.
When changing high-speed interpolation mode, command M code for waiting. After that,
command M code for changing the cancel signal of high-speed interpolation mode.
< Example >
Path 1
:
M300 ;
M450 ;
M301 ;
G00 X50. Z0 ;
G32 Z50. F4.0 ;
M300 ;
M451 ;
M301 ;
:
Path 2
:
M300 ;
M450
M301 ;
;
;
M300 ;
M451 ;
M301 ;
:
Waiting for mode cancel
Cancel high-speed interpolation mode
Waiting for completion of mode cancel
Thread cutting command
Waiting for mode restart
Restart high-speed interpolation mode
Waiting for completion of mode restart