1.Outline
We added external connector for power supply of I/O Link AS-i converter (AS-i Ver2.0).
2. Modified item
I/O Link AS-i converter (AS-i Ver2.0) had one connector for power supply. We added
external connector that branches DC24V for external instrument.
Addition of external connector
for power supply
Existing unit
CP1
1 2 3
+
24V 0V NC
NC : No connection
3. Application
I/O Link AS-i converter (AS-i Ver2.0) A03B-0817-C001
4. Applicable Date
It is applied from March 2003.
EDIT
SHEET
DRAW. NO.
CUST
TITLE
2
2
DESCRIPTION DESIG. DATE
FANUC I/O Link AS-i converrter
(AS-i ver2.0) Addition of external
connector for power supply
A-83120E
Key arrangement
The 24V DC input to CP1(Line A) can be output from CP1(Line B) fo
use branchimg. In this case, the external 24V DC power supply should
have a rating which is equal to the sum of the current consumed by the
control unit and the current used via CP1(Line B)
For external instrument
Specification of connecto
for cable
This is compatible with
existing unit
CP1
1 2 3
+
24V 0V NC
Line B
Line A
+
24V 0V NC
For input of power supply
Specification of connecto
for cable
AMP JAPAN X Key
1-178288-3 (housing)
1-175218-5 (contact)
Specification of connector for cable
AMP JAPAN Y Key
2-178288-3 (housing)
1-175218-5 (contact)
AMP JAPAN X Key
1-178288-3 (housing)
1-175218-5 (contact)