FS16i-LB ソフトウエアの交換について
FS16i-LB Changing for software
2/2
FANUC LTD
A-81053-098
Description Design Date Edit.
01 050203 Andou
Newly
Title
Sheet
Draw. No.
The feedback gain has been raised by becoming small of the pulse average power to reduce the
deflection of power. However, the feedback gain was too high for pulsing on the average power small
(average output < Pc<1/5). And It turned out that the output command signal might fluctuate.
Therefore, even when the pulse average power was small, we corrected software so that the
feedback gain might become constant.
5.注意 Attention
パルスパワーフィードバック機能を無効にした場合には、有効の場合と比較して、すべてのパルス
指令条件において平均パワーが変化し、加工条件が変わります。大半の加工条件は、パルスパワー
フィードバック機能を有効にして正常に動作していますので、不具合の発生時に、一時的に機能を
無効にすると、かえって大きな混乱をまねくことになりますので、注意をお願いいたします。
When the pulsed power feedback function is invalidated, the average power changes under all the
pulse instruction conditions and processing conditions change compared with the case to make this
function effective. The greater part of processing conditions operate normally when the pulsed power
feedback function is an effective setting. Please note that the major disruption will be rather caused
when the function is temporarily invalidated when trouble occurs.