7. Operation
This utility"FromUtil2.EXE" starts from the command line.
The progress situation and the processing result are output to the command line screen and
the specified log file.
The command line syntax for FromUtil2.EXE is as follows:
FromUtil2 [-nNode|-hHost:Port [-tTime]] [-lst|-sav|-del|-lod] [-r“path¥list_file”]
[-service] [“Target_path¥”] [-bkup|-rstr]
[-pw1=MTBpassword] [-pw2=USERpassword] [-f”path¥log_file”]
Option Function
-nNode Specify the Node number at HSSB connection (0..7)
-hHost:Port [-tTime] Specify the Host name/IP address and Port number. When the Timeout
value is not specified, it is assumed as 30 second by default.
-lst If specified, this utility writes the name of System files and User files
contained in the CNC’s FROM into the file specified by “path¥list_file”.
When the file name is written, space” ”, period”.” located on the FROM
program name is changed to underscore”_”.
-sav If specified, this utility reads the System files and User files contained in
the CNC’s FROM, and then places them under “Target_path¥”
according to the file name described in the file, “path¥list_file”.
If –service switch is not specified, the System files will not be read out.
-del If specified, this utility deletes the System files and User files contained
in the CNC’s FROM according to the file name described in the file,
“path¥list_file”.
If –service switch is not specified, the System files will not be deleted.
-lod If specified, this utility writes the System files and User files located
under “Target_path¥” into the CNC’s FROM according to the file name
described in the file, “path¥list_file”.
-r“path¥list_file”
(Note 1)
Specify the PC side file that is referred when the System files and User
files contained in CNC’s FROM are handled by any of the above
switches [-lst|-sav|-del|-lod].
-service Specify this switch in case that the System files contained in the CNC’s
FROM are handled by any of the above switches [-sav|-del].
“Target_path¥” Specify the PC side file location in case that the CNC’s FROM is
handled by any of the above switches [-sav|-lod], or in case that the
CNC’s SRAM is handled by any of the below switches [-bkup|-rstr].
-bkup If specified, this utility reads the CNC’s SRAM data and then saves it
under “Target_path¥”.
When the same name file has been located, the file is overwritten.
-rstr If specified, this utility restores the SRAM data file from “Target_path¥”
into the CNC’s SRAM area.
Ed. Date Design Description FANUC LTD. Sheet 6/9
TITLE
FANUC Open CNC
FROM/SRAM Management Utility for Command
Line Specification
A-79714E
01
04.08.12
New
DRAW.NO.