B–63123EN/01
9. CONTROL FUNCTION
169
When using three–level switching for constant position gain control for
the X– and Y–axes during nibbling, use these parameters to set the
position gains.
These parameters are valid when bit 4 (LPG) of parameter No. 16051 is
set to 1.
16822 Velocity loop integral gain for level 1
16823 Velocity loop integral gain for level 2
16824 Velocity loop integral gain for level 3
[Data type] Word axis
[Valid data range] 1 to 32767
When using three–level switching for constant position gain control for
the X– and Y–axes during nibbling, use these parameters to set the
velocity loop integral gains. (Equivalent to parameter No. 2043)
Only the settings for the X– and Y–axes are valid.
These parameters are valid when bit 5 (VCG) of parameter No. 16051 is
set to 1.
16825 Velocity loop proportional gain for level 1
16826 Velocity loop proportional gain for level 2
16827 Velocity loop proportional gain for level 3
[Data type] Word axis
[Valid data range] –1 to 32767
When using three–level switching for constant position gain control for
the X– and Y–axes during nibbling, use these parameters to set the
velocity loop proportional gains. (Equivalent to parameter No. 2044)
Only the settings for the X– and Y–axes are valid.
These parameter are valid when bit 5 (VCG) of parameter No. 16051 is
set to 1.
16828 Velocity loop integral gain for level 1
16829 Velocity loop integral gain for level 2
16830 Velocity loop integral gain for level 3
16831 Velocity loop integral gain for level 4
16832 Velocity loop integral gain for level 5
16833 Velocity loop integral gain for level 6
16834 Velocity loop integral gain for level 7
[Data type] Word axis
[Valid data range] 1 to 32767