A-56590-1259E FANUC AC SPINDLE MOTOR αi SERIES IP65 MODELS
- 4 -
(*1) The rated output is guaranteed at the rated voltage.
(Amplifier input
200V input: 200/220/230V AC +10% -15%, 50/60 Hz ±1Hz
400V input: 400/480V AC +10% -15%, 50/60 Hz ±1Hz)
If the input voltage fluctuates, it is possible that the rated output cannot be
obtained even when such fluctuations are within the allowable fluctuation range.
(*2) The cycle time is 10 minutes, S3 15%: ON 1.5 minutes, OFF 8.5 minutes,
S3 40%:ON 4 minutes, OFF 6 minutes, and S3 60%: ON 6 minutes,
OFF 4 minutes.
(*3) The rated current is not a guaranteed value but a guideline for the maximum
current at rated output.
(*4) IC code conforms to IEC 34-6.
(*5) IM code conforms to IEC 34-7.
(*6) This is not a guaranteed value but a guideline for the maximum motor output at a
rated supply voltage.
(*7)Type conforms to IEC 34-11.
(*8)Use the motor output shaft below the allowable radial loads. If an excessive load
is applied, consider the use of a support bearing on the machine side to maintain
the long-term reliabilty of the motor. (If an excessive load is applied, it is
possible that an abnormal sound may occur.)
(*9)These values are to be used only as guidance for selecting a power supply module
and are not guaranteed.
(*10)Degree of protection: IP65.