Table 2.5 Error code list (2/3)
Error
code
Meaning
1409 m of ”DO m” or ”END m” exceeds 1 digit.
140A m of ”DO m” or ”END m” is another than 1–3.
140B A code other than a numeric code is found behind DO or END.
140C There is an alphabetic spelling other than a control command and a function.
140D There is an alphabetic spelling of more than 5 characters.
140E EOR is missing at the program end.
140F There is a code which is not used in the program.
1410 The length of the character string exceeds 255.
1411 The internal code exceeds 4 digits.
1412 The internal code is not of a hexadecimal expression.
1413 A non–displayable internal code is commanded.
1414 The command of the character string starting with ’(*’ is not terminated ith ’*)’.
1415 There is an unallowable character between ’(’ and ’)’.
1601 The area of temporary variable used by the executor is insufficient. There are too many addresses including
<Expression> in 1 block NC sentence.
1602 The destination of GOTO is too far. Reduce the program size.
1603 The number of addresses in 1 block NC statement exceeds 50.
1604 The macro variable No. exceeds 6 digits.
1605 The macro variable No. is negative.
1606 There is a decimal point in the macro variable No.
1607 The numeric code after GOTO exceeds 4 digits.
1608 There is a decimal point in the numeric code after GOTO.
1681 GOTO sentences directly designating the sequence No. exceed 100 in one program.
1682 The sequence No. to which jump is commanded by GOTO is missing.
1683 WHILE statement exceed 100 in number in one program.
1684 There are several sequence Nos. to which a jump is commanded by GOTO.
1801 The ROM cassette overflows.
2001 Time has run out for receiving from the PMC writer.
2002 A parity error occurred during receiving from the PMC writer.
2003 An overrun error occurred during receiving from the PMC writer.
2004 A framing error occurred during receiving from the PMC writer.
2005 The PMC writer is not ready. Or the reader/puncher interface cable is not connected.
2006 An error occurred at a transfer to the PMC writer.
2007 A parity error occurred at a transfer to the PMC writer.
2008 The ROM is not erased.
2009 A ROM writing error occurred.
200A A ROM verify error occurred.
200B The ROM cassette is not set.
200C Another ROM cassette than order–made macro is set.
200D The PMC writer edition is wrong.
200E An error occurred in the PMC writer.
200F RESET key is depressed during processing.
2010 An odd number is designated as address or the length for the PMC writer.
2011 Writing was tried exceeding the capacity of ROM cassette connected.
2012 The baud rate is inadequately set.
3000 Normal termination