EDIT.
01
04.03.25
DATE
Suzuki
DESCRIPTION
DESIG.
1st. Edition
TITLE
DRAW.
No.
Connection about Reactor and
Line Filter
A-72562E-0028
FANUC LTD
SHEET
Wrong example 1)
Wrong example 2)
Wrong example 3)
Note
Between the reactor and the Input line regenerative type amplifier, no electrical equipment must
be connected.
There is a possibility that the connected equipment may be damaged and/or malfunction may be
caused on the Input line regenerative type amplifier.
Resistor regenerative
type amplifier (note2)
Resistor regenerative
type amplifier (note2)
Input line regenerative
type amplifier (note1)
The line filter is connected to the
secondary side of the reactor.
There is a possibility that the Resisto
regenerative type amplifiers may be
damaged.
malfunction may be caused on the
Input line regenerative type amplifier.
Line
Filter
note4
Reactor
(note3)
Resistor regenerative
type amplifier (note2)
Resistor regenerative
type amplifier (note2)
The Resistor regenerative type
amplifier is connected to the
secondary side of the reactor.
There is a possibility that the Resisto
regenerative type amplifiers may be
damaged.
malfunction may be caused on the
Input line regenerative type amplifier.
Reactor
(note3)
Input line regenerative
type amplifier (note1)
Input line regenerative
type amplifier (note1)
Some Input line regenerative
type amplifiers are connected to
one line filter.
There is a possibility that the one
Input line regenerative type amplifie
may be damaged.
malfunction may be caused on the
other Input line regenerative type
amplifier.
Reactor
(note4)
Input line regenerative
type amplifier (note1)
2/3