Connection about Reactor and Line Filter Additional Manual Page 3

Additional Manual
EDIT.
01
04.03.25
DATE
Suzuki
DESCRIPTION
DESIG.
1st. Edition
TITLE
DRAW.
No.
Connection about Reactor and
Line Filter
A-72562E-0028
FANUC LTD
SHEET
Note 1) Input line regenerative type amplifier
α series PSM A06B-6077-HXXX, A06B-6087-HXXX
αi series PSM A06B-6110-HXXX
βi series SVPM A06B-6134-HXXX
etc.
Note 2) Resistor regenerative type amplifier (note2)
α series PSMR A06B-6081-HXXX
αi series PSMR A06B-6115-HXXX
α series SVU A06B-6089-HXXX,
α series SVUC A06B-6090-HXXX
βseries SVU A06B-6093-HXXX
βi series SVM A06B-6130-HXXXA06B-6131-HXXX
etc.
Note 3) Reactor
A81L-0001-0133
A81L-0001-0147
A81L-0001-0150
A81L-0001-0122
A81L-0001-0123
A81L-0001-0120
A81L-0001-0124
A81L-0001-0155
A81L-0001-0156
A81L-0001-0157
A81L-0001-0158
A81L-0001-0159
A81L-0001-0160
etc.
Note 4) Line Filter
A81L-0001-0083/3C
A81L-0001-0101/C
A81L-0001-0102
etc.
3/3

Contents Summary of Connection about Reactor and Line Filter Additional Manual

  • Page 1Connection about reactor and line filter 1. Outline The reactor is used for the input line regenerative type amplifier such as αi PSM, and the line filter is used for the resistor regenerative type amplifier such as βi SVM. And miss-connection of reactor and line filter may cause a damage or malfunc
  • Page 2Wrong example 1) Reactor Input line regenerative The Resistor regenerative type (note3) type amplifier (note1) amplifier is connected to the secondary side of the reactor. Resistor regenerative There is a possibility that the Resistor type amplifier (note2) regenerative type amplifiers may be damage
  • Page 3(Note 1) Input line regenerative type amplifier α series PSM A06B-6077-HXXX, A06B-6087-HXXX αi series PSM A06B-6110-HXXX βi series SVPM A06B-6134-HXXX etc. (Note 2) Resistor regenerative type amplifier (note2) α series PSMR A06B-6081-HXXX αi series PSMR A06B-6115-HXXX α series SVU A06B-6089-HXXX, α