2003/07/29 M.Sano
A-79163EN
FANUC Series 30i
Parameter Conversion Support Tool
Title
Drawing No.
Page
DescriptionDate
Edit
12
83
Parameter setting for
FS16i
Parameter setting for FS30i
Axis Setting Axi
s
Setting
X 60000 X 60.000
Y 60000 Y 60.000
Z 60000 Z 6.0000
B 300 B 0.300
C 72 C 0.0072
Table 2. Parameter setting
4. Parameter changed to system common type
Part of the parameter of each path set with FS16i was changed
to the system common type in FS30i. It sets the parameter in the
1st path of FS16i.
5. Parameter to which format is changed by set unit of mm/inch
All set values of each parameter in the parameter file were set
after the address of P in FS16i. Setting the parameter
concerning the unit of mm/inch was changed in FS30i. If it is a
unit of mm, a set value of the parameter is set after the address
of M. If it is a unit of inch, a set value of the parameter is set after
the address of I.
ex) Example of setting parameter No.1220
Parameter of FS16i N01220 A1 P 0 A2 P 0 A3 P 0 A4 P 0
Parameter of FS30i N01220 A1 M0.000 A2 M0.000 A3 M0.000 A4 M0.000
6. Parameter to which meaning of ON/OFF is changed opposite by
bit type parameter
As for a part of the bit type parameter of FS30i, the meaning of
ON/OFF was changed.
7. Parameter converted into the machine group type
A part of the path type parameter of FS16i is changed to the
machine group type parameter in FS30i. The parameter in the
first path of FS16i is converted into the parameter of the
machine group type of FS30i.