B–63122EN/01
29. SAFETY FUNCTIONS
NC FUNCTION
203
Axis stops, and alarm is given.
#2
#0
Move direction
Fig. 29.6.1 (b)
Set the machine coordinate value when the workpiece holder is positioned
at the tool center (punching position) by the parameters.
The detector on the machine automatically detects the positions of the
workpiece holders mounted on the carriage. Values representing the
detected positions are then set in the safety zone parameters.
Carriage
#1 #2 #3 #4
Detector (secured to the machine)
Fig. 29.6.3
The signal for detecting the position of the workpiece holders turns on and
off as workpiece holders #1 to #4 pass the detector as shown in Fig. 29.5.3.
The safety zone is determined from the signal. The position on the X axis
when the signal goes high is regarded as one end of a workpiece holder,
and the position when the signal goes low is regarded as the other end.
Format of workpiece holder detection command
G32X x
F f P p Q q ;
x : X axis move command
f : Feedrate
p : Compensation amount when workpiece holder detection signal
rises
q : Compensation amount when workpiece holder detection signal
falls
29.6.2
Setting the Safety Zone
29.6.3
Automatic Setting of
the Safety Zone