A-79815E
Title
Draw
No.
Ed Date Design Description
Date Nov.09’04 Design. Apprv.
2/5
Page
FANUC Series 30i/31i/32i-MODEL A
Output format improvement of
custom macro variable data
General
The custom macro variable data are output as floating point of IEEE 64bit
data. Therefore, the value of data cannot be confirmed directly as decimal
number.
The number and the value of the macro variable in decimal number can be
output as a comment by setting parameter No.6019#0 after the data usually
output.
Accuracy of the output of the data of the comment is up to 15 digits. The
ranges of output data are eight digits below decimal point and nine digits
above decimal point. When the digits number above the decimal point
exceeds ten, “±OVER FLOW ” is output. When the digits number below
the decimal point exceeds nine, the ninth digit is rounded off.
When the column of "DATA" of the custom macro screen is "DATA
EMPTY", the output becomes "EMPTY".