9. Alarm
No. Message Meaning of data
5373 AURGUMENT CONVERSION
ERROR
In MDI program output for
program restart, macro call
argument cannot be converted into
8 digits.
5374 FSC MODE MISMATCH IN
RESTART
The current mode of flexible
synchronous control is different
from the mode at the program
restart block.
5375 FSC MODE CAN NOT
CHANGED
The flexible synchronous control
mode cannot be changed during the
program restart.
5376 FSC SLAVE AXIS CAN NOT
COMMANDED
The command to slave axis of
flexible synchronous control is not
available.
5377 INVALID COMMAND AFTER
FSC OFF
The command to the axis which
was a slave axis of flexible
synchronous control is specified
after the cancel of synchronization
and before specifying the absolute
command to the axis
5378 INVALID RESTART BLOCK When the specified block of
program restart is the block after
cancellation of the mode of flexible
synchronous control, specify the
block after the absolute command
to the canceled slave axis.
5381 INVALID COMMAND IN FSC
MODE
G27-G30/G30.1/G53 is commanded
to slave axis of flexible synchronous
control. Or, G28 is commanded to
master axis when reference point of
master axis is not established.
Edit
22/22
Data Si
nature
Descri
tion
Improvement of Program restart Specifications
A-90024EN
Drawing No.
Page
Modification
02
Date
Mar/26/05.
Desig.
M. Kobayashi
Apprv.
T. Endo
May/10/05.
FANUC Series 16i/18i/21i-MB/TB
Title