(Example)
Block to be restarted is N100 in a program O100.
Setting of M code groups:
- M10, M11 : Group 2
- M120, M220, M320 : Group 3
- M51 : Group 0 (No group)
• Protection of MDI program
When parameter PMP (No.13117#5) is set to 1 and memory protection
signal (KEY3 <G046#5> or KEY1 <G046#3>) is set to 0, MDI program is
protected after MDI program is generated until the MDI program
execution is completed and CNC mode is changed to MEM, that is, after
program restart MDI program output completed signal SQMPR
<F316#6> becomes “1” until program restart MDI program execution
completed signal SQMPRE <F316#7> becomes “0”.
During MDI program is protected, MDI program can not be edited. If
Insert, Delete or Alter key is pushed, warning “WRITE PROTECT” is
displayed.
Caution
- When parameter KEY (No.3290#7) is set to 0, KEY3 is
used for MDI program protection. And when parameter
KEY is set to 1, KEY1 is used.
- Back ground edit can not be performed after MDI program
is generated until the MDI program execution is completed
and CNC mode is changed to MEM. If softkey [BG-EDT]
is pushed, BP/S alarm 75 (WRITE PROTECT) is
displayed.
M codes to be output
M10
M51
M320
O0100;
M10 -- Group 2
:
M11 -- Group 2
:
M120 -- Group 3
:
M51 -- Group 0
:
M10 -- Group 2
:
M220 -- Group 3
:
M51 -- Group 0
:
M320 -- Group 3
:
:
N100 X10. Y10.; -- The block to be
restarted
Edit
5/22
Data Si
nature
Descri
tion
Improvement of Program restart Specifications
A-90024EN
Drawing No.
Page
Modification
02
Date
Mar/26/05.
Desig.
M. Kobayashi
Apprv.
T. Endo
May/10/05.
FANUC Series 16i/18i/21i-MB/TB