4 Signals
Thermal growth compensation start signal
THML<G356#0>
[Classification] Input signal
[Function
] Thermal growth compensation becomes effective
when this signal is turned on.
When this signal is turned off, thermal growth
compensation is stopped. This signal becomes
effective regardless of the mode, automatic
operation or manual operation.
Thermal growth compensation check signal
MTHML<F356#0>
[Classification] Output signal
[Function
] This signal is turned on and output to PMC when
the thermal growth compensation becomes
effective. This signal is turned off and output to
PMC when the thermal growth compensation is
stopped.
Strobe signal of the Thermal growth compensation along tool vector data
THSTB<G356#1>
[Classification] Input signal
[Function
] When THSTB goes high, the control unit reads the
thermal growth compensation data.
Read end signal of Thermal growth compensation data
THREND<F356#1>
[Classification] Output signal
[Function
] After all the Thermal growth compensation data
are read, the control unit drives the read end signal
THREND high.
NOTES
The thermal growth compensation is not cancelled when this signal is changed
from 1 to 0.
A-79097E
Edit
Apprv. Desig.
Sheet
Title
Draw
No.
Date
Design
Description
Date
FANUC Series 16i–MB, 18i–MB5
Thermal growth compensation
along tool vector Specifications
Jul.11.2003
T.Horie H.Kouzai
8/17