2.3 Direct DVDO
The direct DI/DO that are not transferred through PROFIBUS are prepared on the Power Mate
PROFIBUS board.
These signals has not the communication delay. So these signals should be assigned to emergency
stop, skip signal, high speed interlock or deceleration signals.
The meaning of direct DI signals is different in each type of Power Mate. The DI signals that have
no meaning can be used freely.
As for direct DO signals, only bit 0 and 1 are effective.
2.3.1 Direct signals in case of Power Mate-MODEL D (Single path)
Address 7 6 5 4 3 2 1 0
Xl 000 SKIP *RILK
*DECl
“ESP SKIP4
SKIP3
SKIP2
x1001 “DECZ
YIOOO -
2.3.2 Direct signals in case of Power Mate-MODEL D (dual path)
Address 7 6 5 4 3 2 1 0
X1000 1 SKIP#l 1 *RILK#l 1 *DECl#l ( *ESP#l ( 1 SKIP4#1 1 SKIP3#1 1 SKIPZ#l
Xl 001 SKI P#2 *RILK#Z
*DEC2#2
*ESP#Z
SKIP4#2 SKIP3#2 SKIP2#2
YIOOO -
2.3.3 Direct signals in case of Power Mate-MODEL H
When the parameter number 3001 bit #3 (BIO) is set to I, the following assignment is selected.
Address 7 6 5 4 3 2 I 0
x1000 SKIP
Xl 002
YIOOO -
*RILK *ESP
SKIP4
SKIP3
SKIP2
“DECG
*DECS *DEC4 *DEC3
*DEC2 *DECl