Connection specification between third party encoder (with serial interface) and Separate Detector Interface Unit Additional Manual Page 2

Additional Manual
Title
Sheet
Draw. No.
Connection specification between third party
encoder (with serial interface) and Separate
Detector Interface Unit
33
FANUC LTD
A-56731E-0095
Description Desig. Date Edit.
01 03.07.29 Kikuchi
Connection specification
between third party encoder (with serial interface) and Separate Detector Interface Unit
1. Type of applied technical documents
Spec. No. / Version Name
B-63003JA/04
16i/160i/160is/18i/180i/180is/21i/210i/210is/20i-MODEL A
Connection Manual (Hardware)
B-63523 JA/03
16i/160i/160is/18i/180i/180is/21i/210i/210is-MODEL B / 18i/180i/180is
-MODEL B5 Connection Manual (Hardware)
B-63833JA/02 0i-MODEL B / 0i Mate-MODEL B Connection Manual (Hardware)
B-63173 Power Mate i Connection Manual
B-63323 15i-MODEL A Connection Manual
B-63783 15i-MODEL B Connection Manual
B-63943 30i-MODEL A Connection Manual
2. Summary of Change
Group Name / Outline
New, Add,
Correct,
Delete
Applicable
Data
Basic
Function
Connection specification for third party encoder
(with serial interface)
Correct 2003.07
Optional
Function
Unit
Maintenance
Parts
Notice
Correction
Another

Contents Summary of Connection specification between third party encoder (with serial interface) and Separate Detector Interface Unit Additional Manual

  • Page 1TECHNICAL REPORT (MANUAL) NO. TMS03/027E Date September 29, 2003 General Manager of Servo Laboratory Connection specificationbetween third party encoder (with serial interface) and Separate Detector Interface Unit 1. Distribute this report to the destinations marked with ○: ○ Your information ○ GE F
  • Page 2Connection specification between third party encoder (with serial interface) and Separate Detector Interface Unit 1. Type of applied technical documents Spec. No. / Version Name 16i/160i/160is/18i/180i/180is/21i/210i/210is/20i-MODEL A B-63003JA/04 Connection Manual (Hardware) 16i/160i/160is/18i/180i
  • Page 31. Summary Connection specification between third party encoder (with serial interface) and Separate Detector Interface Unit is modified in order to be common to the connection specification between alpha i series Pulsecoder and alpha i series servo amplifier. Title Connection specification between
  • Page 4Third party encoder Interface (Serial Interface) Separate Detector Interface Unit Third party encoder JF101~JF108 (PCR-EV20MDT) 1 SD 11 2 *SD 12 0V 3 13 4 14 0V 5 REQ 15 6 *REQ 16 0V 7 +6V 17 +6V is the encoders which need battery 8 18 +5V back up. 9 +5V 19 10 20 +5V Cable wiring 1 SD SD 2 *SD *SD 5