Page 1FANUC Series 16i/18i/21i -TB/MB Spindle speed override for each spindle (Improvement of multi-spindle control) Specifications FANUC Series 16i/18i/21i –TB/MB Title Spindle speed override for each spindle (Improvement of multi-spindle) Draw A-79118E No. Edit Date Design Description Sheet 1/5 Date Des
Page 21.General During this function, each spindle speed can be overridden individually. An override value to 0%~254% can be applied. This function can be used when multi-spindle control type C (parameter MSC (No.3713#3)) is set. This function requires multi-spindle control option. 2.Specification When ea
Page 44.Parameter #7 #6 #5 #4 #3 #2 #1 #0 3713 EOV [Data type] Bit, common to all path EOV Each spindle speed override is 0: not used 1: used NOTE 1) Multi-spindle control type C (No.3713#3=1) is necessary to use this function. NOTE 2) When this parameter has been set, the power must be turned off before
Page 55.Note - The multi-spindle control option is necessary to use this function. - In the case of parameter SOV (No.3106#5) (the spindle override value is displayed)=1, 1st spindle speed override value is displayed. - During constant surface speed control, the spindle speed is overridden after it is cla