Edit.
22/26
Date Signature Change
FS16i/18i-MA
Electronic Gear Box 2 Pair Specifications
1999/03/26
A-63501E
H.Shiobara
02
1999/05/17
Pa
e 5 & 11 were corrected. E.Genma
E.Genma
K.Endo
03
1999/1029
Pa
e 8 was corrected
1023 Number of the servo axis for each axis
[Data type] Byte axis
[Valid range] 1 to the maximum number of controlled axes
Specify the number of the servo axis that corresponds to each control axis. Normally, set each servo and
control axis to the same numbers.
For axes under electronic gear box (EGB) control, a pair of two axes must be set. Set these axes as
follows:
Set 1, 3, 5, or 7 for the slave axis. For the dummy axis to be used with the slave axis, set a value
greater than the value set for the slave axis.
NOTE
After setting this parameter, the power must be
turned off then on again.
#7 #6 #5 #4 #3 #2 #1 #0
2011 SYNMOD
[Data type] Bit axis
SYNMOD Specifies the axis on which to perform synchronization when using the electronic
gear box function (EGB).
0: Axis on which to perform synchronization with the EGB.
1: Not an axis on which to perform synchronization with the EGB.
Set 1 for both the EGB slave and dummy axes.
#7 #6 #5 #4 #3 #2 #1 #0
3115 NDPx
[Data type] Bit axis
NDPx Display of the current position for each axis
0: The current position is displayed.
1: The current position is not displayed.
NOTE
When using the electronic gear box function (EGB),
specify 1 for the dummy axis of the EGB to disable