Addition of Warming-up Function in FANUC LASER C Series Additional Manual Page 2

Additional Manual
Addition of warming-up function in
FANUC LASER C series
2/4
FANUC LTD
A-81053E-074
Description Design Date Edit.
01 040610 T.WATANABE
Newly
Title
Sheet
Draw. No.
4. Application
This function can be used from the laser oscillator since the following serial number.
It is necessary to renew software. Confirm the number of software versions is newer than
the following number of versions.
5.Setting of CNC parameter
The warm up function is invalid, when the laser oscillator is shipped. Please confirm the
application model in chapter 4 and set the parameter (TPS, OWU) as follows when you
use this function.
table 1
Parameter No.15015#0 the OWU data form: Bit type the warm up function:.
0: It is invalid.
1: It is effective.
However, it is necessary to set the power calibration effectively (parameter No.15000#4=1) for
executing warm up function..
Parameter No.15015#1 TPS data form: Bit type
Switch of temperature sensor installed in laser oscillator.
0: The cabinet temperature sensor is installed.
1: The low temperature sensor is installed.
Model Serial number of application machine
C1000-E L04710953
C2000-E L04620935 L04620936 L04620937 L04620938 L04620939 L04720947
C4000-E L04640119 L04640124 L04740139
C5000-E After November 2004 (after serial number L0□□50004)
C6000-E L04760225
Model Series Versions
FS16i/160i-LA B8F3 08
B8F5 05 FS16i/160i-LPA
B8F6 02
FS16i/160i-LB B8H1 04
FS16i/160i
-
LPB
B8H5
02
Specification of Laser ParameterNo.15015
Setting ofTPS,OWU
Remarks
With low temperature
sensor
(1,1)
The warming up function
effective

Contents Summary of Addition of Warming-up Function in FANUC LASER C Series Additional Manual

  • Page 1Addition of the warm up function in FANUC LASER C series 1.Outline We will report the newly addition of the warm up function in FANUC LASER C series. The warm up function detects the temperature in the laser oscillator when the laser oscillator is started. And this function is executed the warm up o
  • Page 24. Application This function can be used from the laser oscillator since the following serial number. Model Serial number of application machine C1000-E L04710953~ C2000-E L04620935 L04620936 L04620937 L04620938 L04620939 L04720947~ C4000-E L04640119 L04640124 L04740139~ C5000-E After November 2004
  • Page 31)In case of using old software 1)It is irrelevant to the setting of parameter (TPS,OWU), and operation is the same regardless of the setting. Presence of the low Action of laser oscillator temperature sensor Not equipped. The cabinet temperature alarm is generated, when the (Correct setting) cabine
  • Page 4・C2000-E Low temperature sensor installation position ・C4000-E Low temperature sensor installation position ・C4500-E,C5000-E Low temperature sensor installation position Low temperature sensor ・C6000-E installation position Title Addition of warming-up function in FANUC LASER C series Draw. No. A-81
  • Page 5Title Addition of warming-up function in FANUC LASER C series Draw. No. A-81053E-074 01 040610 T.WATANABE Newly Sheet 5/4 Edit. Date Design Description FANUC LTD