A-79619E
Title
Draw
No.
Ed. Date Design Description
Date Sep.10.’04 Design. Apprv.
50/53
page
FANUC Series 30i/31i-MODEL A
Rotation Area Interference Check
Settings for the movement and rotation axes
Group A movement, 1st axis Y-axis Parameter No. 14910=2
Group A movement, 2nd axis Z-axis Parameter No. 14911=3
Group B rotation axis A-axis Parameter No. 14915=5
Reference position return
Perform a reference position return on each axis.
Positioning of the rotation axis at the reference rotation angle
Rotate the A-axis so that the rectangles to make up interference check group
B become parallel to the Y- and Z-axes.
OK
NG
Z
Y
When the reference rotation angle of the A-axis is determined, set it in the
parameter:
Group B reference rotation angle
Parameter No. 14958=A-axis machine coordinates
Rectangles to make up interference check group A
In the state in which a reference position return is performed on the Y- and
Z-axes, set the rectangles to make up interference check group A.
Interference check group A is represented by two rectangles below.
= +
Rectangle 2 Rectangle 1 Interference check group A