Cut Off the Power Line to Motor at Alpha (HV)i Series SVM Additional Manual Page 2

Additional Manual
Function of interception of the power line to motor at Alpha(HV)i series SVM
1. Overview
So far the external MCC has been necessary to cut the power to motor of the each axis.
The power to the motor can be cut by this function instead of connecting external MCC.
2. Applied SVM
(1) SVM1-10HVi: A06B-6124-H102
(2) SVM1-20HVi: A06B-6124-H103
(3) SVM1-40HVi: A06B-6124-H104
(4) SVM1-80HVi: A06B-6124-H105
3. Circuit and Block diagram
(1) Block diagram
Driver for the
power transisitor
Power transistors
PWM signals
0V
5V
24V
Motor
0V
External
contact
Contact
B
Contact
A
Relay
K50
SVM
CN7-A3
CN7
-
A4
CN7-A2
CN7-
A
1
Monitor
(2) Function
1) The safety relay “K50” operates by external contact signal.”
2) The contact “A” (a contact) of the relay “K50” cuts off the power supply of the driver for
the power transistor.
3) The contact “B” (b contact) of the relay “K50 is used to monitor the status.
(3) Operation of the circuit
When the external contact closes, the contact “A” of the relay “K50” closes. The power
supply of the driver for power transistors turns on, then input for the power transistors are
enabled. The contact “B” is open in this state.
When the external contact is open, the contact “A” cuts off the power supply of the driver
for power transistor, and the power transistors turn off forcedly. The contact “B” closes in
this state.
TITLE
DRAW.
No.
1 / 3
Page
FANUC LTD
DESCRIPTION DESIGN DATE
EDIT
Cut off the power line to motor
at Alpha(HV)i series SVM
A-72562EN-0025
1
st
. edition Hirai 03.02.26 01

Contents Summary of Cut Off the Power Line to Motor at Alpha (HV)i Series SVM Additional Manual

  • Page 1TECHNICAL REPORT(MANUAL) NO.TMS 03/009E Date 2003/02/28 General Manager of Servo Laboratory Function of interception of the power line to motor at Alpha(HV)i series SVM 1. Communicate this report to: Your information only GE Fanuc-N, GE Fanuc-E FANUC Robotics MILACRON Machine tool builder Sales agen
  • Page 2Function of interception of the power line to motor at Alpha(HV)i series SVM 1. Overview So far the external MCC has been necessary to cut the power to motor of the each axis. The power to the motor can be cut by this function instead of connecting external MCC. 2. Applied SVM (1) SVM1-10HVi: A06B-6
  • Page 34. Requirement (1) Please monitor the state of the circuit by the contact “B”. In case the state of the circuit is not monitored, there is a possibility that the motor is energized unexpectedly. (2) This function does not satisfy the requirement for safety standard by itself. MTB should compose the
  • Page 47. Notice (1) The dummy connector to shorted CN7-A1 and CN7-A2 is inserted at shipment. When you do not use this function, the dummy connector must be inserted. In case you put off the dummy connector, the motor can not be operated. (2) Please take care not to short 24V. Cut off the power line to mo