Changing of connection in
FL-C2000C• C3000D for CE marking
01 00.06.12 TOGO Newly
• ••• •• •••• ••
•••••••••
••••• 001/2
Changing of connection in FL-C2000C,C3000D for CE
marking
We report that the connection between oscillator and machine will be changed
in FL-C2000C and C3000D for CE marking.
•Overview•
FL-C2000C and C3000D for CE marking is provided with the terminal:XT20
to connect signals from machine. The terminal:XT20 is changed to the
connector:CNL1 to be common with FL-C4000A and C1000iA for CE marking.
The connection cables between oscillator and machine are reduced to only
CNL1 and COP1 by this change.
Caution) In case of FS16-LB, it is not necessary to connect the ON/OFF
signal of AC200V from
CNC into IF PCB, because ON/OFF status of oscillator is
controlled by the signal
of A1,A2 in CNL1.
•Detail of connector•
CONNECTOR DETAIL
COP1 Connector of I/O signal from CNC.
Connection with the optical fiber.
CP1A It is not necessary to connect this connector from now
on.
(Oscillator
’
s ON/OFF signal with FS16i-L.)
(Connect DC24V controlled by CNC.)
CNL1 Connector between oscillator and machine.
••
••••••••••••
IF
IF
oscillator machin
COP1
CNL1
[after
Connection diagram of
A1 IB1 B1 IB2
A2 SC B2
A3 SHL1 B3 SHL2
A4 RUN1 B4 RUN2
A5 EMS1 B5 EMS2
A6 A1 B6 A2
A7 OFI1 B7 OFI2
A8 PF1 B8 PF2
oscillator machin
COP1
CP1A
*)
OFI1,2
XT20
[before
Connection diagram of
••••
EMS1
PF1
PF2
SC
RUN2
EMS2
A2A1
RUN1
IB2
IB1
SHL2
SHL1
*) When FS16i-L is chosen, connect to
CP1A.
When FS16-LB is chosen, connect to
[u
er
[Lower