Specification Change of Master PCB for FS 0-C (A-77361E/01) Additional Manual Page 3

Additional Manual
5.2 Parameter setting
It is necessary the parameter related to CPU speed is set to High-speed mode. Do
not set to Normal mode.
It is not necessary to set the parameter in case of 0-PC, because 0-PC does not
have this parameter.
T series (TC, TF, TTC, GCC) No.398 bit3=0 : High-speed mode
=1 : Normal mode
M series (MC, GSC) No.32 bit7 =0 : High-speed mode
=1 : Normal mode
5.3 Inapplicable Axis PCB
Axis PCBs as follows are not used.
1/4 axis PCB (only for A/B phase pulse-coder) A16B-2200-0360
1/2 axis PCB (only for A/B phase pulse-coder) A16B-2200-0361
5/6 axis PCB (only for A/B phase pulse-coder) A16B-2200-0370
7/8 axis PCB (only for A/B phase pulse-coder) A16B-2200-0380
7 axes PCB (only for A/B phase pulse-coder) A16B-2200-0381
And, It is possible that the Axis PCB used both as an A/B phase pulse-coder and a
serial pulse-coder is used instead of the Axis PCB only for A/B phase pulse-coder.
1/4 axis PCB A16B-2200-0390
1/2 axis PCB A16B-2200-0391
5/6 axis PCB A16B-2200-0800
7/8 axis PCB A16B-2200-0790
7 axes PCB A16B-2200-0791
In this case, it is necessary to change a digital servo function (software).
5.4 Inapplicable software function
The software function of the Conversational programming for machining is not
applicable in the Series 0-MC system, which have the new master PCB. Therefore it
is not able to be ordered and to be added on the new system that used the new
master PCB, later.
In this case, please order and use the current master PCB.
And, it is not possible to use the new master PCB for Series 0-MF, which have this
software basically. So please order and use the current master PCB, too.
EDIT.
FANUC LTD
SHEET
DRAW. NO. CUST.
TITLE
002/2
DESCRIPTIONDESIG.DATE
A-77361E/01

Contents Summary of Specification Change of Master PCB for FS 0-C (A-77361E/01) Additional Manual

  • Page 1
  • Page 2Specification change of Master PCB (Control type B) for FANUC Series 0-C 1. Summary FANUC has a plan to change the Control B type Master PCB in the some controller of Series 0-C.So the specification number of the Master PCB will be changed. Control A type Master PCB is already changed.(Technical Rep
  • Page 35.2 Parameter setting It is necessary the parameter related to CPU speed is set to High-speed mode. Do not set to Normal mode. It is not necessary to set the parameter in case of 0-PC, because 0-PC does not have this parameter. T series (TC, TF, TTC, GCC) No.398 bit3 =0 : High-speed mode =1 : Normal