FS18i-TB Additional Manual Page 4

Additional Manual
3
3. PMC signals
#7 #6 #5 #4 #3 #2 #1 #0
G272 R08I4 R07I4 R06I4 R05I4 R04I4 R03I4 R02I4 R01I4
#7 #6 #5 #4 #3 #2 #1 #0
G273 SIND4 R12I4 R11I4 R10I4 R09I4
[Classification] Input signal
[Function] SIND4 : Analog voltage is
1: controlled.
0: not controlled.
R01I4~R12I4 : Binary codes are set in these signals for control analog voltage.
Setting range is from 0 to 4095 and can be controlled from 0[V] to
+12.5[V].
During SIND4(G273#7) is set to "1", analog voltage is controlled by
PMC signals.
4. Parameter
Number #7 #6 #5 #4 #3 #2 #1 #0
3710 SANVL
SANVL : Analog voltage output function is
1: applied.
0: not applied.
5. Cautions
(1) When analog voltage output function is applied, analog spindle can not be controlled.
(2) For analog voltage control, spindle control signals for the fourth spindle is used.
(3) When analog voltage is controlled, S analog output function is necessary.
(4) This function is available on both paths of 2-CPU-2-path system.
Edit
Apprv.
Desig.
Sheet
Title
Draw
No.
/ 3
Date
Design
Description
Date
FANUC Series18i-TB
Analog voltage output
A-76264EN
1999.01.25
Kageyama
2
2003.11.13
Kageyama
All modified

Contents Summary of FS18i-TB Additional Manual

  • Page 1FANUC Series 18i-TB Specifications of Analog voltage output Title FANUC Series18i-TB Analog voltage output Draw No. A-76264EN 2 2003.11.13 Kageyama All modified Edit Date Design Description Sheet 0 /3 Date 1999.01.25 Desig. Kageyama Apprv.
  • Page 2FANUC Series 18i-TB Specifications of Analog voltage output Contents 1. OUTLINE ....................................................................... 2 2. ANALOG VOLTAGE OUTPUT ............................................ 2 3. PMC SIGNALS............................................................
  • Page 31. Outline Analog voltage can be controlled by PMC signals. The PMC signals are spindle control signals for the fourth spindle. Analog voltage is output from connector of JA40. To use this function, S analog output function is necessary, but analog spindle can not be controlled. 2. Analog voltage ou
  • Page 43. PMC signals #7 #6 #5 #4 #3 #2 #1 #0 G272 R08I4 R07I4 R06I4 R05I4 R04I4 R03I4 R02I4 R01I4 #7 #6 #5 #4 #3 #2 #1 #0 G273 SIND4 R12I4 R11I4 R10I4 R09I4 [Classification] Input signal [Function] SIND4 : Analog voltage is 1: controlled. 0: not controlled. R01I4~R12I4 : Binary codes are set in these sign