B–62884EN/01
3. OPERATION
229
| $1 ’’ ’INITIALIZE OF SEQUENCE’
Note
Every single quotation mark in the relay comment and coil
comment string must be described as ”$” + ” ’ ” in the
mnemonic file.
(b) Ladder data
1) Description of net comment
The net comment data is specified by ’(*’ and ’*)’ characters.
Characters Means
(* Start of net comment
*) Terminater of net comment
2) Designation of new page (for ladder diagram printing)
Designation of new page for ladder diagram printing must be
described as ”$P” or ”$p” in the mnemonic file.
Characters Means
$P or $p Designation of new page
(for ladder diagram printing)
(a) Parameter
Following example is for PMC-RC4. For other PMCs, see
APPENDIX A FUNCTIONS SPECIFIC TO INDIVIDUAL PMC
MODELS
1) PMC-RC4
2. Counter data type (Binary or BCD)
3. Whether an operator’s panel is used
(YES: Used, NO: Not used)
4. PMC model
(PMC-RC3/PMC-RC4/PMC-RC4
(STEPSEQ))
5. Start address of language program link
control statement data
(0 or 800000 to 8FFFFF
(hexadecimal))
6. Percentage of language program
execution time (1% to 99%)
7. Ladder execution time
(Always 100%)
%@0↓
2 BCD↓
3NO↓
4 PMC – RC4↓
5 000000
650↓
7 100↓
%↓
[EOB]
3.5.8.4
Sample Mnemonic Files
(Single-format)