4. DESCRIPTION OF PARAMETERS
B–63180EN/02
18
#7
0370
#6 #5 #4 #3 #2 #1 #0
PC1
[Data type] Bit
PC1 PC1 If the “DPL/MDI Operation Package” is connected, the CRT display
screen displays:
0 : Absolute coordinates and machine coordinates (using full–size
characters)
1 : Only absolute coordinates (using triple–size characters)
NOTE
If seven or more controlled axes are used, even setting this
parameter to “1” causes the display screen to look the same
as when the parameter is set to “0”.
0380
Time interval at which packets requesting to establish “DPL/MDI Operation
Package” communication are to be sent
[Data type] Word
[Unit of data] msec
[Valid data range] 1000 to 10000 (Usually, set 0, in which case a setting value of 3000 is
assumed.)
0381
Time interval at which packets for verifying the connection of “DPL/MDI Opera-
tion Package” are to be sent
[Data type] Word
[Unit of data] msec
[Valid data range] 1000 to 10000 (Usually, set 0, in which case a setting value of 5000 is
assumed.)
0382 Time–out value used in waiting for a “DPL/MDI Operation Package” response packet
[Data type] Word
[Unit of data] msec
[Valid data range] 1000 to 30000 (Usually, set 0, in which case a setting value of 5000 is
assumed.)
4.4
PARAMETERS OF
DPL/MDI OPERATION
PACKAGE