page
Ed. Date Design Description
Date
Jan.07.’04 Design. Apprv.
12 / 17
FANUC Series 30i-MODEL A
I/O Link
β
manual handle interface
Peri
heral e
ui
ment control interface
A-79352E
Title
Draw
No.
# 2 G2A If the PMC group-10(2nd channel) is assigned for Power Mate or I/O Link
β
, the pulse of I/O Link manual pulse generator is :
0: transferred to group-10.
1: not transferred to group-10.
# 3 G2B If the PMC group-11(2nd channel) is assigned for Power Mate or I/O Link
β
, the pulse of I/O Link manual pulse generator is :
0: transferred to group-11.
1: not transferred to group-11.
# 4 G2C If the PMC group-12(2nd channel) is assigned for Power Mate or I/O Link
β
, the pulse of I/O Link manual pulse generator is :
0: transferred to group-12.
1: not transferred to group-12.
# 5 G2D If the PMC group-13(2nd channel) is assigned for Power Mate or I/O Link
β
, the pulse of I/O Link manual pulse generator is :
0: transferred to group-13.
1: not transferred to group-13.
# 6 G2E If the PMC group-14(2nd channel) is assigned for Power Mate or I/O Link
β
, the pulse of I/O Link manual pulse generator is :
0: transferred to group-14.
1: not transferred to group-14.
# 7 G2F If the PMC group-15(2nd channel) is assigned for Power Mate or I/O Link
β
, the pulse of I/O Link manual pulse generator is :
0: transferred to group-15.
1: not transferred to group-15.
#7 #6 #5 #4 #3 #2 #1 #0
12334 G37 G36 G35 G34 G33 G32 G31 G30
[Input type] Parameter input
[Data type] Bit
Note
When this parameter is set, the power must be turned off before operation
is continued.