page
Ed. Date Design Description
Date
Jan.07.’04 Design. Apprv.
16 / 17
FANUC Series 30i-MODEL A
I/O Link
β
manual handle interface
Peri
heral e
ui
ment control interface
A-79352E
Title
Draw
No.
# 4 G44 If the PMC group-4(4th channel) is assigned for Power Mate or I/O Link
β
, the pulse of I/O Link manual pulse generator is :
0: transferred to group-4.
1: not transferred to group-4.
# 5 G45 If the PMC group-5(4th channel) is assigned for Power Mate or I/O Link
β
, the pulse of I/O Link manual pulse generator is :
0: transferred to group-5.
1: not transferred to group-5.
# 6 G46 If the PMC group-6(4th channel) is assigned for Power Mate or I/O Link
β
, the pulse of I/O Link manual pulse generator is :
0: transferred to group-6.
1: not transferred to group-6.
# 7 G47 If the PMC group-7(4th channel) is assigned for Power Mate or I/O Link
β
, the pulse of I/O Link manual pulse generator is :
0: transferred to group-7.
1: not transferred to group-7.
#7 #6 #5 #4 #3 #2 #1 #0
12337 G4F G4E G4D G4C G4B G4A G49 G48
[Input type] Parameter input
[Data type] Bit
Note
When this parameter is set, the power must be turned off before operation
is continued.
# 0 G48 If the PMC group-8(4th channel) is assigned for Power Mate or I/O Link
β
, the pulse of I/O Link manual pulse generator is :
0: transferred to group-8.
1: not transferred to group-8.
# 1 G49 If the PMC group-9(4th channel) is assigned for Power Mate or I/O Link
β
, the pulse of I/O Link manual pulse generator is :
0: transferred to group-9.
1: not transferred to group-9.