page
Ed. Date Design Description
Date Jan.07.’04 Design. Apprv.
7 / 17
FANUC Series 30i-MODEL A
I/O Link
β
manual handle interface
Peri
heral e
ui
ment control interface
A-79352E
Title
Draw
No.
Parameter on CNC (FS30) side
Caution
・The Change of the parameter LBH (No.7105#5) and the parameter (No.12330
- 12337) is valid after you turn off the power and turn on again.
For example : Even if you change the parameter LBH(No.7105#5)from
1(available) to 0(unavailable), the motor moves according the movement of
the manual handle, till you turn off the power.
#7 #6 #5 #4 #3 #2 #1 #0
7105 LBH
[Input type] Parameter input
[Data type] Bit
Note
When this parameter is set, the power must be turned off before operation
is continued.
# 5 LBH Manual handle feed for the I/O Link
β
by using I/O Link manual pulse
generator is :
0: Unavailable.
1: Available.
#7 #6 #5 #4 #3 #2 #1 #0
12330 G17 G16 G15 G14 G13 G12 G11 G10
[Input type] Parameter input
[Data type] Bit
Note
When this parameter is set, the power must be turned off before operation
is continued.
# 0 G10 If the PMC group-0(1
st
channel) is assigned for Power Mate or I/O Link
β
, the pulse of I/O Link manual pulse generator is :
0: transferred to group-0.
1: not transferred to group-0.